celltype_counts_by_sample.csv contains raw detected-cell counts in the tissue tiles actually processed. Cell types are rows; completed samples are columns.

celltype_fractions_by_sample.csv divides each class count by all detected cells in that completed sample. A nonempty column sums to one. A verified zero-detection completed sample has zero fractions and sums to zero.

Fractions can make composition easier to compare across samples with different detected-cell totals, but they do not correct:

  • biased or unrepresentative tile sampling;
  • different tissue regions or preparation quality;
  • incorrect MPP;
  • model error;
  • batch effects; or
  • failed/missing samples.

For sampled runs, counts are not whole-slide estimates. Do not multiply them by the inverse sampling percentage. Before analysis, check that sampling percentage and seed are consistent and inspect sample_aggregation_audit.csv.

celltype_counts_long.csv is a tidy representation with slide_id, sample_id, class_id, cell_type, and count for included results.